Welcome to Ingeniería Algencal S.L.
Contact us at
+34 955513390

Mass flow measurement network

Red de medición de flujo másico

Mass flow measurement network

  • Volume measurement of gaseous media in ducts, especially for combustion air for combustion applications.
  • With minimal differential pressure loss compared to conventional technology.
  • Short inlet and outlet length for laminar flow. Long air ducts are no longer required.
  • Stainless steel material.
  • Basic temperature range up to 400 °C.
  • Maintenance-free for use in clean air applications.
  • Rectangular and circular grid versions are available.
  • With an increase in the dust particle load, the backtracking (option) can be performed.
  • Connection to the Differential Pressure Transmitter by impulse piping or according to customer's request.
FeatureValue

Material

Stainless steel 1.4404
(other materials upon request)

Pneumatic connection

SV12 cutting ring connection
(other connection types on request)

Types of installation

  • Flange connection.
  • Welding execution.
  • Clamping connection for "Jacobrohr".

Applicable temperature range

+5°C ... +400°C
(other temperature ranges on request)

Measuring means

All non-aggressive, non-explosive gaseous media with known density.

System pressure

-0.5 ... +0.5 bar (negative/positive pressure)

Repetition accuracy

Generally, the repeatability accuracy ≤ +/- 1% of the measured value.

Measuring accuracy

  • Calibrated grids in the test set ≤ +/- 1% of the measured value.
  • Calculated grids +/- 5% of measured value.
  • Locally calibrated grids ≤ +/- 2% of the measured value.
Product approved by: